Selection of Syringe Pump and Points for Attention

When selecting syringe pump, please determine syringe of certain standard according to liquid measure volume. Driver shall be selected based on distributive use method of driver fluid: is it a multichannel or single-channel driver? Do fluid flow and allocation accuracy meet the demand? And consider other elements such as operating environment, installation, etc. Please operate syringe pump according to operating rules, and handle step by step in accordance with specifications to avoid mistakes.


Knowledge of industrial syringe pump


Features of industrial syringe pump: ball screw at grinding level with high travel precision; full-ceramic construction, with anti-corrosion, wear resistance, high temperature resistance, long life service and high loading capacity; programmed operation command which realizes automatic operation easily, supporting the use of instruments and equipment. Why is industrial syringe pump potent? Because normally venous channel shall be established separately in order to avoid incompatibility and eliminate influence on medicine cure effect. Normally, during the process of combined drugs, drugs for infusion pump need a path, which makes a sense of dominance.


Usually, syringe will be neglected in clinical practice, and special syringe will be neglected for industrial syringe pump. Some scholar demonstrated in clinical study that compared with special syringe and before pump tube, non-dedicated tube will affect actual flow rate of trace syringe pump, then relative error of flow rate will increase even twice the number, and especially have a great effect on slow flow speed (1ml/h).


Selection of syringe pump and points for attention


  • Set up infusion program from the start every time replacing liquid.

  • Exempt from alarms for syringe pump. Bubble alarm: close intravenous access, open pump door, eliminate bubble, set catheter, close pump door, open intravenous access and start to transfuse; Finish alarm: set again the volume; Blocking alarm: usually caused by blood returning, pipe bending, filter stoppage, regulator closed, remove blocking reasons; Pump door not closed: close pump door; battery running out: put new batteries.

  • When using infusion pump and opening pump door, except for discharging bubble, replacing tube, withdrawing infusion pump, etc. infusion catheter regulating clip must be clamped to avoid infusion out of control.

  • Recharge and check syringe pump regularly to avoid problems once syringe pump will not be used for a long time.